< Previous10Electrical connectionStandard application: Rooms with one or more heating circuits (< 15 m² per heating circuit)Connection over power contactor | cable length max. 100 m per heating circuit / par value fuse 20 A per heating circuitSpecial application: One room with one heating circuit under 10 m²Direct connection to thermostat | cable length max. 60 m / par value fuse 16 ASpecial application: The residual lengths of cable are NOT connected in the ground, but in of the junction box | The sum of the total cable length is max. 100 m.4455123645123634512366251 Room thermostat2 Socket3 Floor sensor 4 E-NERGY IQ (max. 100 m | < 15 m²) 5 Ending 6 Meter cabinet with contactor (Cutout siwtch 20 A [C-Characteristic] by heating circuit)1 Room thermostat2 Socket3 Floor sensor4 E-NERGY IQ (max. 60 m | < 10 m²)5 Ending 6 Meter cabinet (fuse 16 A 1 Room thermostat2 Socket3 Floor sensor4a Remaining length 14b Remaining length 2 5 Ending6 Meter cabinet with contactor (fuse 20 A [C-character])1254a4b [C-character]) IMPORTANT SAFETY INSTRUCTIONS - Warnings Before carrying out any electrical work, disconnect the power supply and secure it against reconnection. The electrical installation may only be carried out by qualified persons in accordance with the applicable legal requirements. The instal-lation must comply with national and/ or local electrical codes. A residual current device (nominal residual current ≤ 30 mA) is required for each circuit.11Install the floor sensor connection set with contact to the heat conduction plate.In light constructions (for example parquet in direct support) fix the elements completely with glue (e. g. Ecofix by Mapei).Measure the insulation resistance of the hea-ting cable before installation and document this in the commissioning certificate.Lay out edge insulation strips and lay support battens on clean, bearing underground.Separate the arch shaped elements along the score line with a cutter.Lay heating elements over the entire area. Cut elements only in the cutting recess.NOTE COMMISSIONING REPORTFOLLOW SEPARATE INSTRUCTIONSInstallationInsert the heating cable in the junction box and leave minimum 30 cm over.Insert the heating cable stressless. Maximum cable length 100 m.Cut the end of the heating cable and provide it with the end terminal. Only insert the end terminal in straight grooves (not in curves).Supply the head and filling elements with heat conduction plates for a better thermal transfer. Press them firmly against the system elements.Provide the heating cable in the junction box with the connection set. Measure the insulation resistance again und document this. Laid surface. Protect travel paths against com-pression, e.g. with insulating wall panels, until the laying of the load distribution layer.FOLLOW SEPARATE INSTRUCTIONSFOLLOW SEPARATE INSTRUCTIONSmfh systems GmbHHager Feld 849191 Belm-VehrteGermanyFon +49(0)5406|699 95-10Fax +49(0)5406|699 95-90mail@mfh-systems.comwww.mfh-systems.comStand 10 | 2018 – Pay attention to all manufacturer details and laying instructions!© mfh systems GmbH – www.mfh-systems.comSocial Mediamfh systems GmbH is a developer and manufacturer of optimized surface heating systems for heating and cooling. We are an Europe-wide partner for system providers, engineers and craftsmen – and that since 1993. Our objective: the right heating for each customer.E-NERGY IQ INCREASES THE LIVING COMFORTE-NERGY IQ can be individually adjusted and operated room by room. This not only increases your living comfort considerably, but also gives you the opportunity to easily control your energy consumption.E-NERGY IQ CAN BE CONTROLLED EASILYSwitch on E-NERGY IQ only when and where you really need heat. The operation of E-NERGY IQ is very simple via the room thermostat or via App on the way.E-NERGY IQ = HEATING + UNDERFLOOR HEATINGE-NERGY IQ is not only an underfloor heating, but also a full-featured heating system. This means that you do not need a gas connection, no fuel storage tank, no central heating, no heating circuit distributor, etc.E-NERGY IQ SAVES COSTS E-NERGY is completely maintenance-free. In this way, you save subsequent- and maintenance costs. A further advantage: with E-NERGY IQ you do not longer need a boiler room! Thus you gain additional living space.YOUR ADVANTAGESE-NERGY IQ REACTS QUICKLYE-NERGY IQ generates the heat where it is needed: directly in the room. Thanks to its innovative heating technology, E-NERGY IQ enables quick heating and cooling.Next >